MATERIAL SAFETY DATA SHEET
 |
 |
SECTION I - CHEMICAL PRODUCT
AND COMPANY IDENTIFICATION
Trade Name: TATA HIAL50 Brick,
TATA CB MSDS
Number: BNZ-16
Generic Name: High Alumina Refractory Bricks and Shapes Revision
Number: 4
Manufacturer: Tata
Refractories Limited (Head Office) Date Issued: June 4, 2006
Address: Circuit House Area (East) 24
Hour Emergency Number: (800)
424-9300
SECTION II -
COMPOSITION/INFORMATION ON INGREDIENTS
Chemical Name CAS Number % ACGIH / TLV OSHA
/ PEL
Aluminum oxide 1344-28-1 50-55 10 mg/m3 15
mg/m3
Ceramic matrix
(mullite, anorthite, corundum) None 35-40 3 mg/m3 5
mg/m3
Crystalline Silica
(cristobalite) 14464-46-1 10-15 0.05 mg/m3 0.05
mg/m3
Key: TLV = ACGIH, 8 hr. time weighted average (TWA); PEL = OSHA permissible exposure limit.
TLV
and PEL limits are for respirable dust.
SECTION III - HAZARDS
IDENTIFICATION
Emergency Overview: This product contains crystalline silica
which is considered a chronic health hazard by inhalation. The International Agency for Research on
Cancer (IARC) has classified occupational exposures to respirable crystalline
silica as being carcinogenic to humans
(Class 1). This classification is based
on what IARC considered sufficient evidence from epidemiological studies of
humans for the carcinogenicity of inhaled silica in the forms of quartz,
cristobalite and tridymite. Crystalline
silica is also known to cause Silicosis, a non-cancerous lung disease.
HMIS Rating: Health: 1* Fire:
0 Physical Hazard: 0 Other:
0
WHMIS
Class: D-2A - Material
causing other toxic effects (VERY TOXIC - Chronic)
Primary Routes
of Entry: Via respirable dust to
the lungs and respiratory system and via coarse dust and particulate to the
eyes.
Primary Target
Organs: Lungs, respiratory system
and eyes.
Potential Health
Effects:
Inhalation: Long term overexposure to respirable crystalline silica dust may
cause permanent and irreversible lung damage including silicosis.
Skin Contact: Possible dryness or irritation resulting
from long term exposures to product dust.
Eye Contact: A mechanical irritant which can cause
moderate to severe eye irritation.
Ingestion: Non-hazardous when ingested.
Potentially a mild Irritant to the GI tract if excessive quantity is
ingested.
SECTION III - HAZARDS
IDENTIFICATION
Medical Conditions Aggravated
by Exposure: Pre-existing chronic
upper respiratory and lung diseases such as, but not limited to, bronchitis,
emphysema and asthma.
Carcinogenicity: This product contains crystalline silica
which is classified as a class 1, human carcinogen by IARC, as a suspect
carcinogen by NTP and as a possible select carcinogen by OSHA.
SECTION IV - FIRST AID MEASURES
Inhalation: Remove to fresh air. Drink water to clear throat and blow nose to
evacuate dust. If coughing and
irritation develop, call a physician.
Eye Contact: Flush with large amounts of water until
irritation subsides, as least 15 minutes.
See a physician if irritation persists.
Skin Contact: Normal good personal hygiene practices. Wash with mild soap and warm water after
each exposure.
Ingestion: Emergency procedures not normally required. May be a temporary irritant to the GI
system.
SECTION V - FIREFIGHTING MEASURES
NFPA
Rating: Health: 0 Fire: 0 Reactivity: 0 Other: 0
Flashpoint and Method:
This is a non-flammable product LEL: N/Ap UEL: N/Ap
Extinguishing Method Not applicable. Product will not burn.
Special Firefighting Procedures: Not applicable.
Fire or explosion Hazards: The brick products described above are
non-flammable. However, the cardboard
packaging is combustible, and due care should be taken to minimize fire
hazards.
SECTION VI - ACCIDENTAL RELEASE MEASURES
Clean-up Procedures: Pick up or shovel material into waste
container taking care to minimize dust.
Wet down if necessary to control dust.
Vacuum clean dust with equipment fitted with HEPA filter
Personal Precautions: If dusty conditions exist, wear a face mask
approved for use with dusts such as 3M 8511 N-95 or equivalent.
Environmental Precautions: None normally required.
SECTION VII - HANDLING AND STORAGE
Storage Requirements: Store in dry area. Always segregate materials by major hazard class.
Special Sensitivity or
Incompatibility: Avoid contact
with strong acids.
Handling Precautions: Assure proper respiratory protection if dust
potential exceeds PEL/TLV.
SECTION VIII - EXPOSURE CONTROLS/PERSONAL PROTECTION
Respiratory Protection: When over PEL/TLV wear an approved face mask
such as 3M 8511 N-95 or equivalent, to protect against silica and
pneumoconiosis producing dust.
Concentrations of dust that exceed the recommendations of the dust mask
manufacturer will need a higher level of respiratory protection, such as a half
mask respirator with appropriate dust filters.
SECTION VIII - EXPOSURE CONTROLS/PERSONAL PROTECTION
Eye Protection: Wear safety glasses with side shields, goggles
or face shield when cutting, milling or abrading to protect eyes against dust
and particulate.
Skin Protection: Under normal conditions the wearing of
protective gloves and clean, body-covering clothing should be adequate.
Engineering Controls: Maintain sufficient mechanical or natural
ventilation to assure dust concentrations remain below PEL/TLV. Use local exhaust if necessary. Power cutting equipment should be equipped
for wet cutting and if necessary with properly designed dust collection devices.
SECTION IX - PHYSICAL AND CHEMICAL PROPERTIES
Physical Form: Yellowish
solid of variable shapes and size. No
characteristic odor.
Melting Point: >1700 C Specific Gravity: 1.7 - 1.9
Solubility in
Water: Insoluble Evaporation Rate: N/Ap
Stability: Product is stable under normal conditions.
Hazardous Polymerization: Cannot occur.
Incompatibilities: None in designed use.
Decomposition Products: None.
Conditions to Avoid: None in designed use.
SECTION XI - TOXICOLOGICAL/ECOLOGICAL INFORMATION
LD50: N/Av LC50: N/Av
Toxicological Hazards: No toxicological studies of this
specific product have been performed.
Ecological Hazards: Most ingredients in this product are
naturally occurring minerals. Unless
contaminated in service, this product is non-hazardous to the environment.
Teratogenicity, Mutagenicity, other
Reproductive Effects: None known
SECTION XII - DISPOSAL CONSIDERATIONS
Waste Disposal Method: May be disposed in an approved landfill
unless contaminated in service. If
contaminated with hazardous materials, place waste in suitable container. Seal and properly label the waste container. Send the container to an approved
Transportation, Storage and Disposal (TSD) facility via an approved waste
hauler. Be sure manifests have been
completed and an adequate "Paper trail" has been established.
SECTION XIII - TRANSPORTATION INFORMATION
US
DOT Shipping Name: Not regulated DOT
Label: None UN/NA
Number: None
Canadian
TGD Shipping Description: Not
regulated as dangerous goods according to Canadian TDGA
SECTION XIII - TRANSPORTATION INFORMATION
International
Dangerous Goods Information:
IMO:
Not regulated as dangerous goods according to the IMDG Code.
ICAO:
Not regulated as dangerous goods according to the ICAO Technical
Instructions.
SECTION XIV - REGULATORY
INFORMATION
OSHA Status: This product is considered hazardous under
OSHA criteria.
TSCA/CEPA
Status: All components of this
product are included in the TSCA and CEPA Chemical Inventories.
CERCLA
Reportable Quantity: N/Ap
SARA Title III:
Section 302 Extremely Hazardous: This product contains no extremely hazardous
substances as defined and listed in section #302
Section 311/312 Hazard Categories: Reportable as a hazardous substance. Check with your Local Emergency Planning
Committee for reportable quantities.
Section 313 Toxic
Chemicals: This product does not
contain substances which are reportable under Section 313.
WHMIS Information: WHMIS Classification: D-2A - Material
causing other toxic effects (VERY TOXIC - Chronic). This product has been classified in accordance with the hazard
criteria of the Controlled Products Regulations (CPR).
Other Regulatory Classifications:
DSCL (EEC): R36 - Irritating to eyes
R39
- Danger of very serious irreversible effects
R45
- May cause cancer
Reason for Issue: WHMIS 3 year update Approval Date: June 4, 2006
Prepared by: CCG, Inc. Supersedes Date: November 15, 2005
Revision
History: Removal of Product
Stewardship Information, June 4, 2003
Change
to Manufacturer’s Address, November 15, 2005
As
of the date of this document, the foregoing information is believed to be
accurate and is provided in good faith to comply with applicable federal and
state laws. However, no warranty or
representation of law or fact, with respect to such information, is intended or
given.