CS85
Marinite a, c
marinite P
marinite I
marinite m
transite ht
transite 1000
 

Marinite M

Marinite M Fireproof Marine Joiner Panels are lightweight, non-asbestos 4'x 8' sheets designed to provide structural strength and high thermal and acoustical insulating values in a variety of interior marine applications. Formed from calcium silicate with inert fillers and reinforcing agents, Marinite M panels are easily handled and cut to required shapes and sizes.

In addition to high strength and insulating values, Marinite M panels combine ease or erection, fire safety, durability, attractive appearance, and low maintenance for use as bulkheads, linings or ceiling material for new construction and reconversion of passenger vessels, cargo ships, tankers, drill rigs and platforms, plus for new construction and reconversion of U.S.C.G. and Navy vessels.

For greater design flexibility; Marinite M panels can be faced with a variety of decorative finishes including sheet metals and hard or soft plastic laminates. The panels provide an excellent base for melamine veneers, often preferred for their appearance and damage resistance.

Properties

Dimensions

Available Thicknesses

½-2"
Sheet Sizes These sheets are 4' x 8'
Density
pcf 46
kg/cm² m3 737
Modulus of Rupture
psi 800
kg/cm² 56
Compressive Strength
Ultimate load: psi -
Ultimate load: kg/cm² -
@ 5% Deformation: psi 1000
@ 5% Deformation: kg/cm² 70
Moisture
Normal % of dry wt 3.0
Thermal Conductivity  (Mean Temperature, Btu-in/ft2, hr, °F )
400°F 0.81
600°F 0.79
800°F 0.81
1000°F 0.86
Thermal Conductivity  Mean Temperature, W/m°K
204°C 0.12
316°C 0.11
427°C 0.12
538°C 0.12
Shrinkage %: 24 hrs @ 1200°F
Length/width 0.4
Thickness 1.4
Electrical
Volume Resistivity, ohm-cm ASTM D 257 9.8x107
Dielectric Strength, v/mil ASTM D495 45
Screw Holding Strength @ 7/8" penetration
lbs 200
kg 91

The physical and chemical properties of BNZ's materials represent values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Results should not be used for specification purposes.